Actron CP7677 Provozní pokyny Strana 28

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 27
28
Connect BLACK test lead to re-
maining heater pin.
Turn multimeter rotary switch to
200 range.
View reading on display.
Compare reading to manufacturer's
specification in vehicle service
manual.
Remove both test leads from sen-
sor.
6. Connect BLACK test lead to sen-
sor GROUND pin.
If sensor is 1-wire or 3-wire, then
GROUND is sensor housing.
If sensor is 2-wire or 4-wire, then
GROUND is in sensor wiring har-
ness.
Refer to vehicle service manual for
Oxygen Sensor wiring diagram.
7. Connect RED test lead to sensor
SIGNAL pin.
8. Test Oxygen Sensor.
Turn multimeter rotary switch to...
2V range for Zirconia Type Sen-
sors.
200K range for Titania Type
Sensors.
Light propane torch.
Firmly grasp sensor with a pair of
locking pliers.
Thoroughly heat sensor tip as hot
as possible, but not glowing. Sen-
sor tip must be at 660°F to operate.
Completely surround sensor tip
with flame to deplete sensor of
oxygen (Rich Condition).
Multimeter display should read...
0.6V or greater for Zirconia Type
Sensors.
an Ohmic(Resistance) value for
Titania Type Sensors. Reading will
vary with flame temperature.
While still applying heat to sensor,
move flame such that oxygen can
reach sensor tip (Lean Condition).
Multimeter display should read...
0.4V or less for Zirconia Type
Sensors.
an overrange condition for Tita-
nia Type Sensors. (See Setting the
Range on page 6.)
9. Repeat Step 8 a few times to verify
results.
10. Extinguish Flame, let sensor cool,
and remove test leads.
11.Test Results.
Good Sensor:
Heater Circuit resistance is within
manufacturer's specification.
Oxygen Sensor output signal
changed when exposed to a rich
and lean condition.
Bad Sensor:
Heater Circuit resistance is not
within manufacturer's specification.
Oxygen Sensor output signal did
not change when exposed to a rich
and lean condition.
Oxygen sensor output voltage
takes longer than 3 seconds to
switch from a rich to a lean condi-
tion.
Zobrazit stránku 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 34

Komentáře k této Příručce

Žádné komentáře